How can the high humidity and temperature environment in the south ensure the safe operation of the host in the data room, reduce energy consumption, and prolong the service life of the host?

TECHNICAL SERVICES

技术服务

How can the high humidity and temperature environment in the south ensure the safe operation of the host in the data room, reduce energy consumption, and prolong the service life of the host?

  • Categories: Common Problem
  • Time of issue: 2022-04-13 19:20:10
  • Views: 0

Description:

The traditional cooling tower design conditions are 37°C for the inlet water, 32°C for the outlet water, and 28°C for the wet bulb temperature. When extreme weather with high temperature and high humidity occurs in the southern part of the country, the wet bulb temperature often exceeds 30°C. At this time, the traditional cooling tower cannot be used at all. The cooling requirements are met and the energy consumption is greatly increased or even the mainframe is overloaded and shut down, which will cause immeasurable losses to the data room. The temperature in the traditional cooling tower is kept at 35-40 ℃ for a long time in summer, and a large amount of algae and Legionella will be produced in the tower, which will easily reduce the heat exchange efficiency of the host condenser and endanger the health of the maintenance personnel of the cooling tower. Using the high negative pressure forced evaporative low temperature cooling tower produced by our company to replace the existing conventional cooling tower can effectively solve the appeal problem. The high negative pressure forced evaporation low temperature cooling tower reduces the cooling tower outlet water temperature by increasing and adjusting the negative pressure inside the tower body to increase the evaporation intensity in the tower. The minimum outlet water temperature is consistent with the ambient wet bulb temperature. Most of the time, the outlet water temperature can be lowered to below 28°C, ensuring that the main engine is in the best working state, reducing the main engine load, extending the main engine life, reducing the main engine energy consumption, and effectively inhibiting the cooling tower Legionella and algae It can delay the formation of calcium and magnesium ions in the cooling water, and ensure the clean and efficient operation of the cooling tower and the main engine, which is greatly reduced.

Contact Information

Consulting Service Hotline:4006 336 881
Sales Department I:010-61482380
Sales Department II:010-61482310
Personnel Line:010-61482635
After Sales Special Line:010-61488416
Fax Telephone:010-61482381

 

Business Cooperation Email:elyxe@elendoo.com
After Sales Service Email:elsh@elendoo.com
Technical Consultation Mailbox:eljs@elendoo .com
Factory Address:Industrial Park, 22 Zhangzhen street, Shunyi District, Beijing

益冷和众科技(北京)有限公司

Follow official information

Copyright © Elendoo Technology (Beijing) Co., Ltd.   All Rights Reserved.    Record Number:京ICP证16067316号

Website Construction:300.cn     BeiJing    SEO